O.P.
我有一个三菱重工业分裂的管道〜5年旧的系统,在冷却方面的性能很好,但是在加热时,它不断关闭并最终造成了错误。用内部房间的温度为15c,将恒温器设置为20℃,压缩机启动了几分钟,然后切开,触发63H1高压开关截止。在此触发器之后,压缩机在重新启动之前保持了几分钟。 If this happens several times the error message is displayed on the controller (see error message at bottom of post).
Also seems to work OK for longer before the 63H1 switch is thrown when running at a higher fan speed.
I've got a video of what the unit is doing here: https://www.youtube.com/watch?v=DrRRKenklr0
Do these values look reasonable?
Some other points:
+ Unit got new gas ~6months ago after a several year long slow leak out.
+ Tested at the time in cooling only given the season
+ Indoor fan-only mode is fine, as is cooling and drying
+ Manual suggests lack of airflow could cause this, but to rule it out I've tried disconnecting both return and output plenums and let the单位运行而无需任何管道 - 同一问题。
+室外单元线圈清洁
我可以在这里检查的任何东西吗?可悲的是,这项技术的提前时间诊断为4周,它变得冷!
(d)高压开关(63H1)的异常检测控制(63H1)
(i)如果压力升高并运行高压开关(如果在3.15mpa的4.15mpa/cosse上打开高压开关,则在3.15mpa的情况下进行了压缩仪式。 it enters the anomalous stop mode.
When it occurs 5 times within 60 minutes that pressure rises and the compressor is stopped by 63H1.
When 63H1 has been in the open state for 60 minutes continuously, including the stop of compressor.
评论
Hey,
Im going to assume this issue is a protection step due to high temp being到达时到达。确保过滤器干净整洁。通风口?
您是否进入了天花板并检查了管道 - 看看是否有管道被压碎。
制冷剂过多,这些单元可能会被捕获的制冷剂,如果没有正确撤离,如果没有正确地撤离。