O.P.此帖子被编辑
3相SIG能量控制器的典型闲置功耗是什么?当我们睡着时,我的房子在一夜之间画了〜150W,但我注意到电池的排水量超过450W。超过300W的空闲使用情况,或每天超过7kWh。这是正常的吗?
屏幕截图:https://photos.app.goo.goo.gl/jjalseu2eyv2vffnra(忽略今天放电的能量,因为我的大部分晚上都有电池处于处于休眠状态)。我有20kW TP EC与40kWh的电池配对。很想听到其他人看到的三角洲。
谢谢!
这篇文章进行了编辑
大约一周前的Sigen应用程序社区中有一个帖子。 一位用户建议使用逆变器加35W的8KWH电池模块的35W。 This corresponds with what I'm seeing when everything is quiet and the battery is on hold or sitting at backup reserve level, a constant draw of 165-170W for TP inverter and 3 battery modules ie 60+3*35.
Over a day that's approaching 4kWh to run the BESS.
There were also some comments on the Sig AU Facebook page, including unfavourable comparisons with Powerwall which is apparently much more高效。
编辑:在此处找到FB帖子:
https://www.facebook.com/share/p/1b43wnhpvu/
o.p.
是的。对我来说,那将是60+35*5 = 235W。尽管逆变器的怠速抽签会随逆变器的尺寸增加。您有什么尺寸的EC?
您能指出我在Sigen应用程序社区中的帖子吗? The search function isn't very useful.
评论
davsat5 writes...
What size EC do you have?
10kW TP
Could you point me to the post in the Sigen app community?
Set the sort order to Hot, Aust & NZ region, and it should be only a couple of screens down. 用户是Henk。因此,在整个雨天,只有约80%的电池容量可以用来为房屋供电,其余的将用于系统本身。 I think I'll keep the dormancy settings active and just buy 1kWh of electricity at night.
评论
With my 10kW SP inverter and 40kWh battery (5x 8kWh modules) in self-consumption mode I see approximately 135W baseline self-consumption from the stack + 5% DC-AC loss.
In standby mode (commanded via Modbus)是85W。该应用程序中有节能模式,该模式警告了增加备份切换时间的权衡。我不确定“待机”模式是否等同于此,因为我在此模式下测试了备份,并且它已经足够快,以至于我或任何设备都注意到了。 85W似乎仍然足够高,以至于它可以保持足够的电源电子功能,以迅速发挥作用。如果是这样,我就无法参与并测量这种节能模式。
o.p.
有趣的是,一旦与Sig设置为Sig。
现在,我会尝试“待机模式”。
现在,当房屋负载下降到150w以下时,我已经让电池保持沉降,这是150w的下降,这是夜间大约7个小时的夜晚,我就会降低。白天,您不会注意到太阳能擦拭(即使在下雨天)。因此,只剩下约8H,没有太阳能,房屋负荷> 150W(夏季的时间少得多),这导致电池系统消耗的2.4kWh。实际上不是那么糟糕。
澳洲中文论坛热点
- 新西兰总理:出世在新西兰的新纳粹Thomas Sewell是“挺蹩脚的人”,但那是澳洲的问题
- 新西兰总理拉克森称新纳粹Thomas Sewell是坏人,但是没对要求把他从澳大利亚遣返到诞生国去的呼吁置评。
- 撞穿学校栅栏害死十一岁男孩的司机不必坐牢
- 一位女司机撞穿学校栅栏、害死了11岁男孩,被罚2000元罚金、撤消驾照,不必坐牢。Jack Davey 的父母去了