O.P.
大家好,
Madimack出售许多具有可变速度的泳池泵(也是现有泳池泵的附加泵),使用Modbus进行通信 - 但是试图从它们中获得任何in Infromation in Modbus Map and Registers等,这是一个以令人沮丧的方式进行的。
units.
I suspect they are an oem/reseller anyway – but i do not have the details as to who manufactures them
Craig
评论
O.P.
curto writes...
Has anyone else achieved this and have access to the modbus map for these units.
I suspect they are an oem/reseller anyway – but i do not have the details as to who manufactures them
OK some further information for future generations
After digging through several layers of support at Madimack they now claim that this is a misprint (and has been for the last 5 years) and that their units do not support modbus – even though the diagrams clearly show an RS485 terminal.
Found another unit being sold在西澳看起来相同并与那里的那个人交谈 - 他的线索比Madimack少 - 但确实找到了制造商(似乎只是一个) - 他们的名字是Aquagem - 他们有一个合法的网站,还有一个合法的网站。
也已经给他们发送了消息,也让我们发送了电子邮件 - 让我们看到任何答案。编辑
嘿curto,
我相信Madimack是由Aquark制作的。我有一个由费尔兰(Fairland)制造的类似单元,该单元被更名为AES热泵。 All these units seem to share virtually identical controllers and Modbus register maps.
I have controlled my heat pump via RS485 MODBUS by simply making a cable up (it uses a JST XH2.54 connector with three pins needed – B/A/GND) and sending some basic control commands – on, off, change temp etc.
When I get some time, I have a MODBUS TCP to Modbus RTU适配器,我将连接到热泵,以便我可以使用家庭助手通过TCP/IP来控制它。
让我知道您是否还有其他问题。
cheers
matt
hi matt,我可以找到任何模特的文档,您可以找到任何modbus的文档,您已经找到了MADBUS的MADIMPING/MADPAPPING appping for Micapping。我将要自己安装一个。
这篇文章是编辑
hi buzzmack,
我发现的信息并不是针对Madimack的特定信息,我发现的文档也适用于Fairland Heat Pumps。似乎所有在该一般区域生产的热泵都使用具有几乎相同的Modbus地图寄存器的相似控制器。该地区周围的各个人都与各自的制造商保持联系,并获得了具有很多共同点的电子表格。这是我发现的: -
这里的这个散布 - 来自此处的这篇文章,在这里的遗产论坛上 - 先生 - siLence-siLence-full inverter-pool-heater
在其他地方,我在其他地方找到了一个与此.xls文件的链接。 similarities, check out the repo it comes from there – enboer/DomoticzFairlandModbus
Then there's this post here HomeAsistant Controlling a Fairland heatpump eliminating Tuya that again has some documentation that looks similar to previous info
This repo here is a great one with lots of pictures explaining the hardware side of things – rstcologne's ESP MODBUS Fairland Heat Pump controller
For the initial testing I used a USB to RS485 adaptor that I got off eBay years ago for a different project, this worked just fine and is compatible with just about every OS out there now – DTECH USB 2.0 to RS22/485 Adaptor – however for the final installation I used a WiFi MODBUS TCP to MODBUS RTU adaptor that is a very nice little unit, and cheap 也!它称为原始的PW11-H,它是一个不错的DIN轨安装装置,需要240V,可以轻松安装与游泳池附近的其他240V电源设备一起安装 - Protoss-PW11您可以在Aliexpress和Ebay上找到这些可用的,并且可以在.au
Cheers上提供。 Buzzmack?评论
If you don't fancy installing home assistant there is also the option to use tuya-api to mqtt which is a bit more generic.
评论
I joined the forum just to post this info, as I'm considering buying the same pool pump and controlling it via modbus and Home Assistant and node-red。
看起来Madimack是Aquagem的OEM版本:
https://poolbutiken。
https://www.poolklu
for:
https://poolbutiken.se/w
It looks fairly straightforward but unfortunately the functionality looks quite limited compared to the amount of controls available via the app. You can only manually control the pump flow rate and read some information about errors, but that's probably enough to circulate water.
I believe the app is Tuya based even though they don't advertise it, which means there is a chance that the pump contains a TYWExS chip, which mean you could flash it with Tasmota and skip the whole modbus thing to gain local control.
评论
I have a Madimack热泵并通过家庭助理远程控制。不确定这是否是有用的信息!
kopy78写信...
我有一个madimack热泵并通过家庭助手远程控制。
hi ki opopy78图亚整合。我认为与云中的HA中的默认集成在一起,但是您可以花更多的精力来设置本地集成。 YouTube上有很多教程如何做,但是我没有任何使用Tuya的教程。我有兴趣知道,通过当地的Tuya是否比Modbus提供的控制更多。
O.P.
对不起 - 没有跟上这个线程,现在就看到了它。
现在,人们在这里销售了一些
而且他们还会单独出售控制器 - Madimack似乎并没有意识到,控制器支持Modbus超过Rs485
您可以从其他人那里购买控制器(包括eBay上的人们的原始OEM单元) - 有两种型号 - 有两种型号 - 一种用于最大泵为1100W的泵,而另一个型号则是2kw
2)就像由Tuya控制的孟一样 - 在过去的三年中,我一直在使用Tuya通过节点红色整合来控制我的单元 - 但在11月转移到Modbus,这是很棒的。
我打算购买可变速度控制器(Aquagem)之一,以将其添加到SPA泵中,以将其与pook up poss up poss poss poss poss poss poss一起(po)(pook)(pook iT pook)(pop)(pop)(pop)(pop)(poply)(po) This will obviously vary dependant on the speed of water flow, speed of the compressor, ambient temp and water temps – hence why i have moved the heatpump to to Modbus and intend to do the same for the pressure pump so all of this can be juggled有效。 craig
有人是否有人拥有Madimack变量池泵,如果可以的话,您会推荐它们吗?
我的泳池泵正在出路(viron P320)
Inverflo Pro状态的手册:
RS485地址170(0xAA)
160-190(0xa0-0xbf)(0xa0-0xbf),每个步骤by 1 by 1 by 1 by 1 by Speed Contory。 If more than one external control is enabled, the priority is as below:
Digital Input >Analog Input > RS485 > Panel control
PIN 1 Red Digital Input 4
PIN 2 Black Digital Input 3
PIN 3 White Digital Input 2
PIN 4 Grey Digital Input 1
PIN 5 Yellow Digital Ground
PIN 6 Green RS485 A
PIN 7 Brown RS485 B
引脚1流量和30〜120%,以5%增量
引脚2流量和30〜120%,以5%增量为单位
引脚3流量和30〜120%,以5%增量
数字输入:
pin pin pin pin 5 pin pin pin pin pin pin 5 pin pin 4 pin pin pin pin pin pin pin 5 pin pin pin 5 pin;如果断开连接,数字控制器将无效;
当PIN3与PIN5连接时,泵将必须以100%的速度运行。如果断开连接,则控制优先级将重返面板控制;
PIN2与PIN5连接时,泵将必须以80%的速度运行;如果断开连接,e控制优先级将重返面板控制;
PIN1与PIN5连接时,将强制以40%的速度运行泵;如果断开连接,则控制优先级将重返面板控制;
可以根据参数设置对输入的能力(PIN1/PIN2/PIN3)进行修改。
i计划使用切换到地面的数字输入来运行我的数字输入,但会稍后调查RS485。写信...
我相信Madimack是由Aquark制作的。我有一个由Fairland制作的类似单位
正确。
澳洲中文论坛热点
- 悉尼部份城铁将封闭一年,华人区受影响!只能乘巴士(组图)
- 据《逐日电讯报》报导,从明年年中开始,因为从Bankstown和Sydenham的城铁将因Metro South West革新名目而
- 联邦政客们具有多少房产?
- 据本月早些时分报导,绿党副首领、参议员Mehreen Faruqi已获准在Port Macquarie联系其房产并建造三栋投资联