O.P.
我们有一个室内空间Brivis He30i,它在我们的房子里,当我们在2013年购买时,它一直在完美无缺。重置。
我们得到了一项技术,他说水泵已经失败了,您再也无法获得零件,直到(显然是1998年的年份)必须更换 - 花费$ 7,000。
第一件事:“水泵”?真的吗??? I smell BS:
Then a few days later I tried it again and it ran perfectly for several hours until I switched it off manually as we left home.
I found a Brivis service document (link below) which says zilch about water pumps, but says the following which suggests its flame sensor or gas pressure problem:
Auto EMS Flame Sensing – Error 46, 50, 70, 71
背景:
错误46和50表明主火焰传感器在点火时没有看到
稳定的火焰。错误70和71可以表明火焰不在
备用传感器上,或者在N-G1/LO中发生故障/故障。火焰传感器
这些错误的问题和其他原因在本服务手册的N-G1/LO误差
代码部分中得到很好的描述。
这些错误的最常见原因是从主
供应或不正确的气体阀设置的低气压。 (For valve adjustment problems, contact T.S.G.).
On Auto-EMS Models, the cross-lighter can heat up and lift and contact the back-up
flame sensor causing an Error 70/71.
Action:
For MPS Models – when the unit is running on Drive Level 15, ensure that
inlet pressure to the valve is no lower than 1 kPa.如果压力低于1 kPa,
,则需要与气体实用程序联系和/或管道需要升级。
对于自动EMS型号,请检查备用火焰传感器是否是新型的类型(探针
指向新样式支架左图),并且在R.H.S. S. S. S. S. S. S. S.歧管
tab(陶瓷体应最终坐在不在其上方的拉链燃烧器旁边)。
注意:
有时杆可能无法正确放置在火焰中。如果
确保其在火焰。
https://www.avitech.com.au/m
我怎么知道我们的加热器是MPS还是Auto-Ems(这是什么意思)?
您是否从Brivis获得了服务技术来查看它或其他随机? Brivis Tech很可能能够来源。您确定他们说水泵?
O.P.
服装称为高地气体。 He definitely said water pump.
评论
mashley writes...
The outfit was called Highlands Gas.
Contact Brivis and get their tech out.
评论
O.P.
They are Rinnai/Brivis specialists, now the same company as Springwood气:
https://www.highlandsgas.com.au
https://springwoodgas.com.au
澳洲中文论坛热点
- 悉尼部份城铁将封闭一年,华人区受影响!只能乘巴士(组图)
- 据《逐日电讯报》报导,从明年年中开始,因为从Bankstown和Sydenham的城铁将因Metro South West革新名目而
- 联邦政客们具有多少房产?
- 据本月早些时分报导,绿党副首领、参议员Mehreen Faruqi已获准在Port Macquarie联系其房产并建造三栋投资联